Sunday, 16 August 2020

Why we improve power factor

 Low power factor means poor electrical efficiency. The lower the power factor, the higher the apparent power drawn from the distribution network.

When low power factor is not corrected, the utility must provide the nonworking reactive power in addition to the working active power. This results in the use of larger generators, transformers, bus bars, wires, and other distribution system devices that otherwise would not be necessary.
As the utility's capital expenditures and operating costs are going to be higher, they are going to pass these higher expenses to industrial users in the form of power factor penalties and higher utility bills.

Tuesday, 3 March 2020

Electrical Material List | Electrical Consumable list


S.No
Description
UOM
A
Cables & Wires:

1
1 core x 1.0 sqmm single strand, FR, flexible Cu wire
Coil
2
1 core x 2.5 sqmm single strand, FR, flexible Cu wire
Coil
3
1 core x 4 sqmm single strand, FR flexible Cu wire
Coil
4
1 core x 4 sqmm multi strand, FR, flexible Cu wire
Coil
5
1 core x 16 sqmm multi strand FR, flexible Cu wire
mtrs
6
1 core x 35 sqmm multi strand FR, flexible Cu wire
mtrs
7
1 core x 50 sqmm multi strand FR, flexible Cu wire
mtrs
8
2 core x 1.5 sq.mm un armored, multi strand, Cu, FR, PVC flexible cable
mtrs
9
2 core x 2.5 sq.mm un armored, multi strand, Cu, FR, PVC flexible cable
mtrs
10
3 core x 1.5 sqmm un armored, multi strand, Cu, FR, PVC flexible cable
mtrs
11
3 core x 2.5 sqmm un armored, multi strand, Cu, FR, PVC flexible cable
mtrs
12
3 core x 4 sqmm un armored, multi strand, Cu, FR, PVC flexible cable
mtrs
13
3 core x 6 sqmm un armored, multi strand, Cu, FR, PVC flexible cable
mtrs
14
4 core x 1.5 sqmm un armored, multi strand, Cu, FR, PVC flexible cable
mtrs
15
4 core x 2.5 sqmm un armored, multi strand, Cu, FR, PVC flexible cable
mtrs
16
4 core x 4 sqmm un armored, multi strand, Cu, FR, PVC flexible cable
mtrs
17
4 core x 6 sqmm un armored, multi strand, Cu, FR, PVC flexible cable
mtrs
18
4 core x 10 sqmm un armored, multi strand, Cu, FR, PVC flexible cable
mtrs
19
4 core x 16 sqmm un armored, multi strand, Cu, FR, PVC flexible cable
mtrs
20
8 gauge copper wire for earthing
kg
21
10 Gauge copper wire for earthing
kg
22
4 pair communication twisted cable
mtrs
23
5 pair communication twisted cables
mtrs
24
10 pair communication twisted pair cables
mtrs
25
20 pair communication twisted pair cables
mtrs
26
50 pair communication twisted pair cables
mtrs
27
Telephone line cord 5 meter
mtrs
28
Telephone line cord 10 meter
mtrs
29
Telephone receiver cord
mtrs

shiva tandava stotram in tamil



சிவ தாண்டவ தோத்திà®°à®®் à®‡à®°ாவணனால் à®‡à®¯à®±்றப்பட்டதாகச் சொல்லப்படுà®®்[1] à®ªுகழ்பெà®±்à®± துதி ஆகுà®®். இது à®šிவபெà®°ுà®®ானின் à®…ழகையுà®®் ஆற்றலையுà®®் புகழ்ந்து பாடுà®®் à®šà®™்கத à®®ொà®´ிப்பாடலாக à®µிளங்குகின்றது

ஜடா டவீ கலஜ் ஜல ப்ரவாஹ பாவித ஸ்தலே
கலே வலம்ப்ய லம்பிதாà®®் புஜங்க துà®™்க à®®ாலிகாà®®்
டமட் டமட் டமட் டமன் னிநா தவட் டமர் வயம்
சகாà®° சண்ட தாண்டவம் தனோது னஃ சிவஃ சிவம் 1 |

ஜடா கடாஹ ஸம்ப்à®°à®® ப்ரமண் ணிலிà®®்ப நிà®°்ஜரீ
விலோல வீச்சி வல்லரீ விà®°ாஜ à®®ான à®®ூà®°்த்தனி
தகத் தகத் தகஜ் ஜ்வலல் லலாட பட்ட பாவகே
கிà®·ோà®° சந்த்à®° à®·ேகரே ரதிஃ ப்ரதிக்ஷணம் மம 2

தரா தரேந்த்à®° நந்தினீ விலாஸ பந்து பந்துà®°
ஸ்புரத் திகந்த ஸந்ததி ப்à®°à®®ோத à®®ான à®®ானஸே
க்à®°ுபா கடாக்à®· தோரணீ நிà®°ுத்த துà®°்த à®°ாபதி
க்வசித் தீகம்பரே மனோ வினோதமேது வஸ்துனி 3

ஜடா புஜங்க பிà®™்கள ஸ்புரத் பணா மணி ப்ரபா
கடம்ப குà®™்குà®® த்ரவ ப்ரலிப்த திக்வதூ à®®ுகே
மதாந்த ஸிந்து ரஸ்புரத் வகுத்தரீ யமேதுà®°ே
மனோ வினோத மத்புதம் பிபர்து பூத பர்தரி 4

ஸஹஸ்à®° லோச்சன ப்ரப்à®°ுத் யசேà®· லேக சேகர
ப்ரஸூன தூளி தோரணீ விதூ ஸராந்த்à®°ீ பீடபூஃ
புஜங்க à®°ாஜ à®®ாலயா னிபத்த ஜாட ஜூடக
ஸ்à®°ியை சிà®°ாய ஜாயதாà®®் சகோரபந்து சேகர 5

லலாட சத்வர ஜ்வலத் தனஞ்ஜய ஸ்புலிà®™்க பா
நிபீத பஞ்ச ஸாயகம் நமன் னிலிà®®்ப நாயகம்
சுதா மயூக லேகயா விà®°ாஜமான சேகரம்
மஹா கபாலி ஸம்பதே ஸிà®°ோ ஜடா லமஸ்துனஃ 6

கராள பால பட்டிகா தகத் தகத் தகஜ் ஜ்வல
தனஞ்ஜயாà®®் ஹுதீ க்à®°ுத ப்ரசண்ட பஞ்ச ஸாயகே
தரா தரேந்த்à®° நந்தினீ குசாக்à®° சித்à®° பத்ரக
ப்ரகல்பனைக ஸில்பினி த்à®°ிலோச்சனே ரதிà®°் மம 7

நவீன à®®ேக மண்டலீ நிà®°ுத்த துà®°்தர ஸ்புரத்
குஹூ நிà®·ீதி நீதமஃ ப்ரபந்த பந்த கந்தரஃ
நிலிà®®்ப நிà®°்ஜரீ தரஸ் தனோது க்à®°ுத்தி சிந்துரஃ
கலா நிதான பந்துரஃ ஸ்à®°ியம் ஜகத் துரந்தரஃ 8

ப்ரபுல்ல நீல பங்கஜ ப்ரபஞ்ச காலிà®® ப்ரபா
வலம்பி கண்ட கண்டலீ à®°ுசிப் ரபத்த கந்தரம் |
ஸ்மர்ச்சிதம் புரஸ்ச்சிதம் பவஸ்ச்சிதம் மகச்சிதம்
கஜச்சி தாந்தக ச்சிதம் தமந்தக ச்சிதம் பஜே 9

அகர்வ ஸர்வ மங்களா கலா கதம்ப மஞ்ஜரீ
ரஸ ப்ரவாஹ à®®ாதுà®°ீ விஜ்à®°ுà®®்பணா மது வ்ரதம்
ஸ்மராந்தகம் புà®°ாந்தகம் பவாந்தகம் மகாந்தகம்
கஜாந்தகாந்த காந்தகம் தமாந்த காந்தகம் பஜே 10

ஜயத் வதப்à®° விப்à®°à®® ப்ரமத் புஜங்க மஸ்ரவஸ
த்வினிà®°்க மத்க்à®°à®® ஸ்புரத் கராள பால ஹவ்ய வாத்
திà®®ித் திà®®ித் திà®®ித் வனன் à®®்à®°ுதங்க துà®™்க மங்கள
த்வனி க்à®°à®® ப்ரவர்தித ப்ரச்சண்ட தாண்டவஃ சிவஃ 11

ஸ்புà®°ுஷத் விசித்à®° தல்பயோà®°் புஜங்க à®®ௌக்திக ஸ்ரஜோà®°்
கரிà®·்ட ரத்ன லோà®·்டயோஃ சூக்à®°ுத் விபக்à®· பக்ஷயோஃ
த்à®°ுணாரவிந்த சக்à®·ுஸோ ப்ரஜா மஹீ மஹேந்த்ரயோஃ
ஸமாà®®் ப்ரவர்திகஃ கடா சதாசிவம் பஜாà®®்யஹம் 12

கதா நிலிà®®்ப நிà®°்ஜரீ நிகுஞ்ச கோதரே வஸன்
விà®®ுக்த துà®°்மதி ஸதா ஸிரஃ ஸ்த மஞ்சலிà®®் வஹன்
விலோல லோல லோச்சனோ லலாà®® பால லக்னகஃ
சிவேதி மந்த்à®° à®®ுச்சரண் கதா ஸுகீ பவாà®®் யஹம். 13

இமம் ஹி நித்யமேவ à®®ுக்த à®®ுத்தமோத்தமம் ஸ்தவம்
பதன் ஸ்மரண் ப்à®°ுவண் நரோ விசுத்தி à®®ேதி ஸந்ததம்
ஹரே குà®°ௌ ஸுபக்தி à®®ாசு யாதி நான்யதா கதிà®®்
விà®®ோஹனம் ஹி தேஹினாà®®் ஸு சங்கரஸ்ய சிந்தனம். 14


Thursday, 20 February 2020

How to select MCCB or MCB for Motor ?

How to select MCCB or MCB for Motor ?

The selection depends upon the starting method 

1 . In case of DOL starting method , we have to chose the MCCB rating 2 - 3 times of the rated                 motor current rating ( Because motor draw 3-5 times of current than the rated current at starting )

2 . In case of STAR_DELTA or VFD , then we have to choose the MCCB rating 1.5  times of the             rated motoe current rating .

Reason : 

                * Why we are selecting the MCCB rating greater than the actual motor current rating                               means that in case of full load the MCCB will be running in full load current so there are                     possibility to trip . so we are increasing the rating of the MCCB  so that it can run in its                      70-80 % of the rated current .

                * MCCB's and MCB's are not designed for motor protection . You need to use OLR
                   ( Over Load Relay ) or MPCB ( Motor Protection Circuit Breaker ) .

Related Articles :

                             1 . What are the uses of a MCB ?
                             2 . What are the types of MCB ?
                             3 . Difference between ELCB & RCCB ?
                             4 . Difference between MCB & MCCB ?

Sunday, 16 February 2020

Star Delta starter control wiring in tamil

Star Delta starter control wiring in tamil


                           This video will show  you How to Make automatic star delta starter using 3 No.of
 3 pole contactor, MCB and OLR. in tamil.




Related Videos 












How to make a Star Delta starter power wiring in Tamil

Star Delta starter power wiring in Tamil 


                      This video will show  you how to make a Star Delta Starter power wiring in Tamil . Please visit and subscribe my YouTube channel.




How to connect DC Analogue Voltmeter in tamil

How to connect DC Analogue Voltmeter


This video will show you how to connect a DC Voltmeter in Tamil Language.

Please watch, share and subscribe our YouTube Channel for more Videos. rselvam66






Find AC Line Fault , Neutral Fault & Earth Fault in Tamil

Fault Detector

This below video will show you How to use Line fault detector.This detector finds fault in your Alternating current system.
 1. Line fault - Voltage
 2. Neutral fault
 3. Earth Fault

Please watch and subscribe rselvam66



                             2 . FRLSH Cable
\                            3 . How power factor correction works (APFC )
                             4 . Circuit Breaker 



Circuit Breaker

Circuit Breaker

Introduction :

                            A circuit breaker is an automatically operated electrical switch designed to protect an electrical circuit  from damage caused by excess current from an overload or short circuit. Its basic function is to interrupt current flow after a fault is detected. Unlike a fuse, which operates once and then must be replaced, a circuit breaker can be reset (either manually or automatically) to resume normal operation.

Origins :

                           Circuit breakers are made in varying sizes, from small devices that protect low-current circuits or individual household appliance, up to large switchgear designed to protect high voltage circuits feeding an entire city. The generic function of a circuit breaker,RCD or a fuse, as an automatic means of removing power from a faulty system is often abbreviated as OCPD (Over Current Protection Device). Its purpose was to protect lighting circuit wiring from accidental short circuits and overloads.Interconnection of multiple generator sources into an electrical grid required development of circuit breakers with increasing voltage ratings and increased ability to safely interrupt the increasing short-circuit currents produced by networks. 

Operations :


                                     All circuit breaker systems have common features in their operation, but details vary substantially depending on the voltage class, current rating and type of the circuit breaker.

                             The circuit breaker must first detect a fault condition. In small mains and low voltage circuit breakers, this is usually done within the device itself. Typically, the heating or magnetic effects of electric current are employed. Circuit breakers for large currents or high voltages are usually arranged with protective relay pilot devices to sense a fault condition and to operate the opening mechanism. These typically require a separate power source, such as a battery, although some high-voltage circuit breakers are self-contained with current transformer, protective relays, and an internal control power source.

                   Contacts are made of copper or copper alloys, silver alloys and other highly conductive materials. Service life of the contacts is limited by the erosion of contact material due to arcing while interrupting the current. Miniature and molded-case circuit breakers are usually discarded when the contacts have worn, but power circuit breakers and high-voltage circuit breakers have replaceable contacts.

Standard current ratings :

Circuit breakers are manufactured in standard sizes, using a system of preferred numbers to cover a range of ratings. Miniature circuit breakers have a fixed trip setting; changing the operating current value requires changing the whole circuit breaker. Larger circuit breakers can have adjustable trip settings, allowing standardized elements to be applied but with a setting intended to improve protection. For example, a circuit breaker with a 400 ampere "frame size" might have its overcurrent detection set to operate at only 300 amperes, to protect a feeder cable.
 The commonly available preferred values for the rated current are1A,2A,4A, 6 A, 10 A, 13 A, 16 A, 20 A, 25 A, 32 A, 40 A, 50 A, 63 A, 80 A, 100 A, and 125 A. The circuit breaker is labeled with the rated current in amperes, but excluding the unit symbol, A. Instead, the ampere figure is preceded by a letter, B, C, or D, which indicates the instantaneous tripping current — that is, the minimum value of current that causes the circuit breaker to trip without intentional time delay (i.e., in less than 100 ms), expressed in terms of In.
Type Instantaneous tripping current
B Above 3 In
C Above 5 In up to and including 10 In
D Above 10 In up to and including 20 In
K Above 8 In up to and including 12 In
For the protection of loads that cause frequent short duration (approximately 400 ms to 2 s) current peaks in normal operation.
Z Above 2 In up to and including 3 In for periods in the order of tens of seconds.
For the protection of loads such as semiconductor devices or measuring circuits using current transformers.

 Types of circuit breaker :        

                         Many classifications of circuit breakers can be made, based on their features such as voltage class, construction type, interrupting type, and structural features.

  • Low-voltage circuit breakerss
  • Magnetic circuit breakers
  • Thermal magnetic circuit breakers
  • Magnetic-hydraulic circuit breakers
  • Common trip breakers
  • Medium-voltage circuit breakers
  • High-voltage circuit breakers
  • Sulfur hexafluoride (SF6) high-voltage circuit breakers
  • Disconnecting circuit breaker (DCB)
  • Carbon dioxide (CO2) high-voltage circuit breakers